Description
A Bosch Siemens condenser dryer doesn’t heat up while the drum is rotating and the program seems to run normally. Often the fault starts with occasional insufficient heating, after which the dryer eventually only blows cold air.
First, check the following points:
1. Disassemble the back panel, meaning the cover at the heating element.
2. Loosen the screw on the plug, carefully pull the plug out, and measure the black sensor. This should indicate OL, so no measurable resistance.
3. Measure the heating element on the three connection pins. They should show resistance or beep when using a continuity tester.
Are the connections fine and does the measurement of the heating element show no issues? Then the cause is usually the circuit board. Often one or two relays can be seen to have turned black. This is usually not the cause, but the result of other weak points on the circuit board.
Therefore, have the circuit board serviced for € 59.95. Various components are replaced and components that were made too lightly are strengthened.
Send your circuit board to EUROMAXX and we will service it for € 59.95.